<?xml version="1.0" encoding="UTF-8"?>
<borehole>
	<name>Validation QA and QC Examples</name>
	<id>Validation QA and QC Examples</id>
	<boreholeID>Validation QA and QC Examples:BH-05 TRANS-QAQC</boreholeID>
	<easting>0</easting>
	<northing>0</northing>
	<eastextent>1000</eastextent>
	<northextent>1000</northextent>
	<mapeasting>0</mapeasting>
	<mapnorthing>0</mapnorthing>
	<mapeastextent>1000</mapeastextent>
	<mapnorthextent>1000</mapnorthextent>
	<localunits>1</localunits>
	<mapunits>11</mapunits>
	<client></client>
	<clientid></clientid>
	<status></status>
	<spatialreferencecode></spatialreferencecode>
	<datecreated></datecreated>
	<datemodified></datemodified>
	<projecttemplate></projecttemplate>
	<sectiontemplate></sectiontemplate>
	<maptemplate></maptemplate>
	<boreholetemplate></boreholetemplate>
	<viewtemplate></viewtemplate>
	<address></address>
	<city></city>
	<state></state>
	<country></country>
	<postalcode></postalcode>
	<tables>
		<table name="LOG_Borehole">
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="BoreholeName">BH-05 TRANS-QAQC</column>
				<column name="WellSymbol">56</column>
				<column name="XCoord">568420.5</column>
				<column name="YCoord">4812435.8</column>
				<column name="MapXCoord">-80.2415</column>
				<column name="MapYCoord">43.5178</column>
				<column name="Elevation">312.6</column>
				<column name="Depth">12</column>
				<column name="StartDepth">0</column>
				<column name="DepthPerPage">12</column>
				<column name="NoElevData">0</column>
				<column name="Template">846213759402</column>
				<column name="TemplateVersion">1</column>
				<column name="StartPage">1</column>
				<column name="DeviationSurvey">0</column>
				<column name="ShowDevSurvey">0</column>
				<column name="DepthScale">0</column>
				<column name="DepthUnits">1</column>
				<column name="ElevUnits">1</column>
				<column name="DateCreated">0</column>
				<column name="DateModified">0</column>
				<column name="Password"></column>
				<column name="Location">Highway 7, Station 12+450, eastbound shoulder</column>
				<column name="WellStatus">Transportation Geotechnical Borehole</column>
				<column name="SpudDate">46248</column>
				<column name="Operator">DOT Geotechnical Drilling Contractor</column>
				<column name="Lic_API"></column>
				<column name="LogSleuthWell">0</column>
				<column name="CompletionDate">46248</column>
				<column name="ScheduleID">-1</column>
				<column name="Uploaded">0</column>
				<column name="Diameter">150</column>
				<column name="DrillingMethod">Hollow Stem Auger</column>
				<column name="SamplingStart">0.5</column>
				<column name="SamplingType">SS</column>
				<column name="SampleLength">0.6</column>
				<column name="SampleInterval">1.5</column>
			</entry>
		</table>
		<table name="LOG_BoreholeStatus">
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="LifecycleStatus">1</column>
				<column name="ValidationStatus">3</column>
				<column name="QualityStatus">1</column>
				<column name="CompletenessStatus">72</column>
				<column name="LockStatus">0</column>
				<column name="DashboardStatus">2</column>
				<column name="CompletenessPercent">72.2222222222222</column>
				<column name="ValidationErrorCount">2</column>
				<column name="ValidationWarningCount">2</column>
				<column name="ConfidenceScore">54</column>
				<column name="AssignedTo"></column>
				<column name="AssignedToID">0</column>
				<column name="AssignedToDate">0</column>
				<column name="AssignedBy"></column>
				<column name="AssignedByID">0</column>
				<column name="DataEntryBy">Admin</column>
				<column name="LastValidatedBy">Admin</column>
				<column name="LastValidationDate">46250.5057067014</column>
				<column name="ReviewedBy"></column>
				<column name="ReviewedBYID">0</column>
				<column name="LastReviewedDate">0</column>
				<column name="ReviewedByRole"></column>
				<column name="ReviewedByTitle"></column>
				<column name="ReviewedByOffice"></column>
				<column name="ApprovedBy"></column>
				<column name="LastApprovedDate">0</column>
				<column name="ApprovedBYID">0</column>
				<column name="ApprovedByRole"></column>
				<column name="ApprovedByTitle"></column>
				<column name="ApprovedByOffice"></column>
				<column name="LastModifiedDate">46250.5057144676</column>
				<column name="IsDirty">0</column>
			</entry>
		</table>
		<table name="LOG_BoreholeValidationResults">
			<entry>
				<column name="ValidationResultID">1</column>
				<column name="ValidationRunID">1</column>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RuleID">R-730</column>
				<column name="Severity">2</column>
				<column name="Category">COMPLETENESS</column>
				<column name="Message">Sample ID is required</column>
				<column name="AffectedTable">Samples</column>
				<column name="AffectedRecordID">4</column>
				<column name="AffectedDataType">Sample</column>
				<column name="AffectedField">SampleNumber</column>
				<column name="RuleTarget">Sample ID is required</column>
				<column name="DepthFrom">6.3</column>
				<column name="DepthTo">-999</column>
				<column name="IsResolved">0</column>
				<column name="ResolutionNotes">Enter a unique sample ID.</column>
				<column name="RuleName"></column>
				<column name="RuleVersion"></column>
				<column name="Priority">100</column>
				<column name="Explanation"></column>
				<column name="PotentialCause"></column>
				<column name="PotentialResolution"></column>
				<column name="ResolutionType">0</column>
				<column name="ActualValue"></column>
				<column name="ExpectedValue">Non-empty sample ID</column>
				<column name="ConfidenceScore">-1</column>
				<column name="RequiresReview">0</column>
				<column name="RequiresApproval">0</column>
				<column name="CanOverride">1</column>
				<column name="OverrideReasonRequired">0</column>
				<column name="DocumentationRequired">0</column>
				<column name="EscalationLevel">0</column>
				<column name="ResultStatus">0</column>
				<column name="ResolvedBy"></column>
				<column name="ResolvedDate">0</column>
				<column name="OverrideReason"></column>
				<column name="HelpTopic"></column>
				<column name="CreatedDate">46250.4602797338</column>
			</entry>
			<entry>
				<column name="ValidationResultID">2</column>
				<column name="ValidationRunID">1</column>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RuleID">R-731</column>
				<column name="Severity">2</column>
				<column name="Category">LAB_QC</column>
				<column name="Message">Duplicate sample ID detected</column>
				<column name="AffectedTable">Samples</column>
				<column name="AffectedRecordID">3</column>
				<column name="AffectedDataType">Sample</column>
				<column name="AffectedField">SampleNumber</column>
				<column name="RuleTarget">Duplicate sample ID detected</column>
				<column name="DepthFrom">4.8</column>
				<column name="DepthTo">-999</column>
				<column name="IsResolved">0</column>
				<column name="ResolutionNotes">Sample ID duplicates record 3.</column>
				<column name="RuleName"></column>
				<column name="RuleVersion"></column>
				<column name="Priority">100</column>
				<column name="Explanation"></column>
				<column name="PotentialCause"></column>
				<column name="PotentialResolution"></column>
				<column name="ResolutionType">0</column>
				<column name="ActualValue">BH05-SS-02</column>
				<column name="ExpectedValue">Unique sample ID</column>
				<column name="ConfidenceScore">-1</column>
				<column name="RequiresReview">0</column>
				<column name="RequiresApproval">0</column>
				<column name="CanOverride">1</column>
				<column name="OverrideReasonRequired">0</column>
				<column name="DocumentationRequired">0</column>
				<column name="EscalationLevel">0</column>
				<column name="ResultStatus">0</column>
				<column name="ResolvedBy"></column>
				<column name="ResolvedDate">0</column>
				<column name="OverrideReason"></column>
				<column name="HelpTopic"></column>
				<column name="CreatedDate">46250.4602797338</column>
			</entry>
			<entry>
				<column name="ValidationResultID">1</column>
				<column name="ValidationRunID">2</column>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RuleID">R-730</column>
				<column name="Severity">2</column>
				<column name="Category">COMPLETENESS</column>
				<column name="Message">Sample ID is required</column>
				<column name="AffectedTable">Samples</column>
				<column name="AffectedRecordID">4</column>
				<column name="AffectedDataType">Sample</column>
				<column name="AffectedField">SampleNumber</column>
				<column name="RuleTarget">Sample ID is required</column>
				<column name="DepthFrom">6.3</column>
				<column name="DepthTo">-999</column>
				<column name="IsResolved">0</column>
				<column name="ResolutionNotes">Enter a unique sample ID.</column>
				<column name="RuleName">SampleIDRequired</column>
				<column name="RuleVersion">1.0</column>
				<column name="Priority">100</column>
				<column name="Explanation">A sample identifier is required for traceability, laboratory linkage, chain of custody, and defensible QA/QC.</column>
				<column name="PotentialCause">The sample identifier may not have been entered, imported, or mapped from the source record.</column>
				<column name="PotentialResolution">Review the field and laboratory records, enter the verified sample identifier, and confirm that linked results reference the same identifier.</column>
				<column name="ResolutionType">2</column>
				<column name="ActualValue"></column>
				<column name="ExpectedValue">Non-empty sample ID</column>
				<column name="ConfidenceScore">0.9</column>
				<column name="RequiresReview">1</column>
				<column name="RequiresApproval">1</column>
				<column name="CanOverride">0</column>
				<column name="OverrideReasonRequired">1</column>
				<column name="DocumentationRequired">1</column>
				<column name="EscalationLevel">2</column>
				<column name="ResultStatus">0</column>
				<column name="ResolvedBy"></column>
				<column name="ResolvedDate">0</column>
				<column name="OverrideReason"></column>
				<column name="HelpTopic">ValidationRules/R-730</column>
				<column name="CreatedDate">46250.5057067014</column>
			</entry>
			<entry>
				<column name="ValidationResultID">2</column>
				<column name="ValidationRunID">2</column>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RuleID">R-731</column>
				<column name="Severity">2</column>
				<column name="Category">LAB_QC</column>
				<column name="Message">Duplicate sample ID detected</column>
				<column name="AffectedTable">Samples</column>
				<column name="AffectedRecordID">3</column>
				<column name="AffectedDataType">Sample</column>
				<column name="AffectedField">SampleNumber</column>
				<column name="RuleTarget">Duplicate sample ID detected</column>
				<column name="DepthFrom">4.8</column>
				<column name="DepthTo">-999</column>
				<column name="IsResolved">0</column>
				<column name="ResolutionNotes">Sample ID duplicates record 3.</column>
				<column name="RuleName">DuplicateSampleIDDetected</column>
				<column name="RuleVersion">1.0</column>
				<column name="Priority">100</column>
				<column name="Explanation">Duplicate identifiers can associate results with the wrong sample and compromise traceability.</column>
				<column name="PotentialCause">The identifier may have been copied to another sample, reused during import, or assigned before the final sample sequence was known.</column>
				<column name="PotentialResolution">Compare the affected samples with field sheets and chain-of-custody records, assign the correct unique identifiers, and update all linked laboratory data.</column>
				<column name="ResolutionType">0</column>
				<column name="ActualValue">BH05-SS-02</column>
				<column name="ExpectedValue">Unique sample ID</column>
				<column name="ConfidenceScore">0.9</column>
				<column name="RequiresReview">1</column>
				<column name="RequiresApproval">1</column>
				<column name="CanOverride">0</column>
				<column name="OverrideReasonRequired">1</column>
				<column name="DocumentationRequired">1</column>
				<column name="EscalationLevel">2</column>
				<column name="ResultStatus">0</column>
				<column name="ResolvedBy"></column>
				<column name="ResolvedDate">0</column>
				<column name="OverrideReason"></column>
				<column name="HelpTopic">ValidationRules/R-731</column>
				<column name="CreatedDate">46250.5057067014</column>
			</entry>
			<entry>
				<column name="ValidationResultID">3</column>
				<column name="ValidationRunID">2</column>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RuleID">R-801</column>
				<column name="Severity">1</column>
				<column name="Category">CROSS_DATASET</column>
				<column name="Message">Subgrade moisture content exceeds optimum moisture by the permitted tolerance</column>
				<column name="AffectedTable">Remarks</column>
				<column name="AffectedRecordID">2</column>
				<column name="AffectedDataType">Moisture Content</column>
				<column name="AffectedField">MoistureContent/OptimumMoistureContent</column>
				<column name="RuleTarget">Subgrade moisture content exceeds optimum moisture by the permitted tolerance</column>
				<column name="DepthFrom">2.2</column>
				<column name="DepthTo">-999</column>
				<column name="IsResolved">0</column>
				<column name="ResolutionNotes">Subgrade moisture exceeds optimum moisture tolerance.</column>
				<column name="RuleName">SubgradeMoistureAboveOptimum</column>
				<column name="RuleVersion">1.0</column>
				<column name="Priority">60</column>
				<column name="Explanation">Subgrade moisture materially above optimum can reduce achievable compaction and pavement support.</column>
				<column name="PotentialCause">Natural moisture, optimum moisture, depth linkage, material role, test method, or configured tolerance may be incorrect or the subgrade may be excessively wet.</column>
				<column name="PotentialResolution">Verify the paired moisture values and test method at the same depth, confirm the agency tolerance, and assess drying, aeration, stabilization, or undercut requirements.</column>
				<column name="ResolutionType">0</column>
				<column name="ActualValue">22.6% (5.1 percentage points above optimum)</column>
				<column name="ExpectedValue">&lt;= 19.5% (OMC 17.5% + tolerance 2%)</column>
				<column name="ConfidenceScore">0.75</column>
				<column name="RequiresReview">1</column>
				<column name="RequiresApproval">0</column>
				<column name="CanOverride">1</column>
				<column name="OverrideReasonRequired">1</column>
				<column name="DocumentationRequired">1</column>
				<column name="EscalationLevel">1</column>
				<column name="ResultStatus">0</column>
				<column name="ResolvedBy"></column>
				<column name="ResolvedDate">0</column>
				<column name="OverrideReason"></column>
				<column name="HelpTopic">ValidationRules/R-801</column>
				<column name="CreatedDate">46250.5057067014</column>
			</entry>
			<entry>
				<column name="ValidationResultID">4</column>
				<column name="ValidationRunID">2</column>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RuleID">R-802</column>
				<column name="Severity">1</column>
				<column name="Category">GEOTECHNICAL</column>
				<column name="Message">Subgrade CBR is below the applicable design criterion</column>
				<column name="AffectedTable">Remarks</column>
				<column name="AffectedRecordID">1</column>
				<column name="AffectedDataType">California Bearing Ratio</column>
				<column name="AffectedField">CBR</column>
				<column name="RuleTarget">Subgrade CBR is below the applicable design criterion</column>
				<column name="DepthFrom">2.2</column>
				<column name="DepthTo">-999</column>
				<column name="IsResolved">0</column>
				<column name="ResolutionNotes">Subgrade CBR is below the applicable design criterion.</column>
				<column name="RuleName">SubgradeCBRBelowCriterion</column>
				<column name="RuleVersion">1.0</column>
				<column name="Priority">60</column>
				<column name="Explanation">Subgrade CBR below the design criterion may indicate inadequate pavement support and requires engineering review.</column>
				<column name="PotentialCause">The CBR result, soaked or unsoaked condition, sample depth, subgrade designation, or selected agency criterion may be incorrect, or the subgrade may be weak.</column>
				<column name="PotentialResolution">Verify the test result and method, sample linkage and applicable criterion, then assess stabilization, replacement, undercut, drainage, or pavement redesign.</column>
				<column name="ResolutionType">0</column>
				<column name="ActualValue">3%</column>
				<column name="ExpectedValue">&gt;= 5%</column>
				<column name="ConfidenceScore">0.75</column>
				<column name="RequiresReview">1</column>
				<column name="RequiresApproval">0</column>
				<column name="CanOverride">1</column>
				<column name="OverrideReasonRequired">1</column>
				<column name="DocumentationRequired">1</column>
				<column name="EscalationLevel">1</column>
				<column name="ResultStatus">0</column>
				<column name="ResolvedBy"></column>
				<column name="ResolvedDate">0</column>
				<column name="OverrideReason"></column>
				<column name="HelpTopic">ValidationRules/R-802</column>
				<column name="CreatedDate">46250.5057067014</column>
			</entry>
		</table>
		<table name="LOG_BoreholeValidationRuns">
			<entry>
				<column name="ValidationRunID">1</column>
				<column name="ProjectValidationRunID">-1</column>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="ValidationType">1</column>
				<column name="ValidationEngineVersion">1.0.0</column>
				<column name="StartedDate">46250.4602796875</column>
				<column name="CompletedDate">46250.4602797338</column>
				<column name="DurationMS">4</column>
				<column name="ErrorCount">2</column>
				<column name="WarningCount">0</column>
				<column name="Passed">0</column>
				<column name="TriggeredBy">Admin</column>
			</entry>
			<entry>
				<column name="ValidationRunID">2</column>
				<column name="ProjectValidationRunID">-1</column>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="ValidationType">1</column>
				<column name="ValidationEngineVersion">2.0.0</column>
				<column name="StartedDate">46250.5057066551</column>
				<column name="CompletedDate">46250.5057067014</column>
				<column name="DurationMS">4</column>
				<column name="ErrorCount">2</column>
				<column name="WarningCount">2</column>
				<column name="Passed">0</column>
				<column name="TriggeredBy">Admin</column>
			</entry>
		</table>
		<table name="LOG_CanstratLog">
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">0</column>
				<column name="CanstratLog"></column>
			</entry>
		</table>
		<table name="LOG_Lithology">
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">1</column>
				<column name="TopDepth">0</column>
				<column name="BottomDepth">0.18</column>
				<column name="Name">ASPHALT</column>
				<column name="Name2">PAVEMENT</column>
				<column name="Description">ASPHALT CONCRETE pavement; two lifts; minor oxidation and transverse cracking.</column>
				<column name="PlainDescription">ASPHALT CONCRETE pavement; 
two lifts; minor oxidation and 
transverse cracking.
</column>
				<column name="Classification"></column>
				<column name="Lithology">Asphalt</column>
				<column name="Color">Black</column>
				<column name="Odour">Not Perceptible</column>
				<column name="Porosity"></column>
				<column name="Consistency">Dense</column>
				<column name="VertAlign">3</column>
				<column name="HorzAlign">6</column>
				<column name="TitleHAlign">6</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">1</column>
				<column name="LineColor">0</column>
				<column name="StratumCode">1</column>
				<column name="StratumLibrary">USCS</column>
				<column name="StratumCode2">0</column>
				<column name="StratumLibrary2"></column>
				<column name="ContactAngle">0</column>
				<column name="FillSize">1</column>
				<column name="FillSize2">1</column>
				<column name="StratumFGColor">0</column>
				<column name="StratumBGColor">4210752</column>
				<column name="StratumFGColor2">0</column>
				<column name="StratumBGColor2">16777215</column>
				<column name="StratumLineStyle">6</column>
				<column name="StratumLineWidth">1</column>
				<column name="StratumLineColor">0</column>
				<column name="SplitAngle">90</column>
				<column name="PercentageSplit">50</column>
				<column name="SplitLineStyle">0</column>
				<column name="SplitLineColor">0</column>
				<column name="SplitLineWidth">1</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">2</column>
				<column name="TopDepth">0.18</column>
				<column name="BottomDepth">0.65</column>
				<column name="Name">GRANULAR A</column>
				<column name="Name2">BASE</column>
				<column name="Description">Crushed sand and gravel GRANULAR A base; compact; moist.</column>
				<column name="PlainDescription">Crushed sand and gravel 
GRANULAR A base; compact; moist.
</column>
				<column name="Classification"></column>
				<column name="Lithology">Sand and Gravel</column>
				<column name="Color">Brown Grey</column>
				<column name="Odour">Not Perceptible</column>
				<column name="Porosity"></column>
				<column name="Consistency">Compact</column>
				<column name="VertAlign">3</column>
				<column name="HorzAlign">6</column>
				<column name="TitleHAlign">6</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">1</column>
				<column name="LineColor">0</column>
				<column name="StratumCode">1</column>
				<column name="StratumLibrary">USCS</column>
				<column name="StratumCode2">0</column>
				<column name="StratumLibrary2"></column>
				<column name="ContactAngle">0</column>
				<column name="FillSize">1</column>
				<column name="FillSize2">1</column>
				<column name="StratumFGColor">0</column>
				<column name="StratumBGColor">12632256</column>
				<column name="StratumFGColor2">0</column>
				<column name="StratumBGColor2">16777215</column>
				<column name="StratumLineStyle">6</column>
				<column name="StratumLineWidth">1</column>
				<column name="StratumLineColor">0</column>
				<column name="SplitAngle">90</column>
				<column name="PercentageSplit">50</column>
				<column name="SplitLineStyle">0</column>
				<column name="SplitLineColor">0</column>
				<column name="SplitLineWidth">1</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">3</column>
				<column name="TopDepth">0.65</column>
				<column name="BottomDepth">1.4</column>
				<column name="Name">GRANULAR B</column>
				<column name="Name2">SUBBASE</column>
				<column name="Description">Sand and gravel GRANULAR B Type II subbase; trace silt; compact; moist.</column>
				<column name="PlainDescription">Sand and gravel GRANULAR B Type 
II subbase; trace silt; compact; 
moist.
</column>
				<column name="Classification"></column>
				<column name="Lithology">Sand and Gravel</column>
				<column name="Color">Brown</column>
				<column name="Odour">Not Perceptible</column>
				<column name="Porosity"></column>
				<column name="Consistency">Compact</column>
				<column name="VertAlign">3</column>
				<column name="HorzAlign">6</column>
				<column name="TitleHAlign">6</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">1</column>
				<column name="LineColor">0</column>
				<column name="StratumCode">1</column>
				<column name="StratumLibrary">USCS</column>
				<column name="StratumCode2">0</column>
				<column name="StratumLibrary2"></column>
				<column name="ContactAngle">0</column>
				<column name="FillSize">1</column>
				<column name="FillSize2">1</column>
				<column name="StratumFGColor">0</column>
				<column name="StratumBGColor">1411839</column>
				<column name="StratumFGColor2">0</column>
				<column name="StratumBGColor2">16777215</column>
				<column name="StratumLineStyle">6</column>
				<column name="StratumLineWidth">1</column>
				<column name="StratumLineColor">0</column>
				<column name="SplitAngle">90</column>
				<column name="PercentageSplit">50</column>
				<column name="SplitLineStyle">0</column>
				<column name="SplitLineColor">0</column>
				<column name="SplitLineWidth">1</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">4</column>
				<column name="TopDepth">1.4</column>
				<column name="BottomDepth">5.5</column>
				<column name="Name">CL</column>
				<column name="Name2">SUBGRADE</column>
				<column name="Description">Brown silty CLAY, trace sand; firm to stiff; moist; native subgrade.</column>
				<column name="PlainDescription">Brown silty CLAY, trace sand; firm to 
stiff; moist; native subgrade.
</column>
				<column name="Classification"></column>
				<column name="Lithology">Silty Clay</column>
				<column name="Color">Brown</column>
				<column name="Odour">Not Perceptible</column>
				<column name="Porosity">Fine pores</column>
				<column name="Consistency">Firm to Stiff</column>
				<column name="VertAlign">3</column>
				<column name="HorzAlign">6</column>
				<column name="TitleHAlign">6</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">1</column>
				<column name="LineColor">0</column>
				<column name="StratumCode">10</column>
				<column name="StratumLibrary">USCS</column>
				<column name="StratumCode2">0</column>
				<column name="StratumLibrary2"></column>
				<column name="ContactAngle">0</column>
				<column name="FillSize">1</column>
				<column name="FillSize2">1</column>
				<column name="StratumFGColor">0</column>
				<column name="StratumBGColor">9276813</column>
				<column name="StratumFGColor2">0</column>
				<column name="StratumBGColor2">16777215</column>
				<column name="StratumLineStyle">6</column>
				<column name="StratumLineWidth">1</column>
				<column name="StratumLineColor">0</column>
				<column name="SplitAngle">90</column>
				<column name="PercentageSplit">50</column>
				<column name="SplitLineStyle">0</column>
				<column name="SplitLineColor">0</column>
				<column name="SplitLineWidth">1</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">5</column>
				<column name="TopDepth">5.5</column>
				<column name="BottomDepth">12</column>
				<column name="Name">TILL</column>
				<column name="Name2">FOUNDATION SOIL</column>
				<column name="Description">Dense grey-brown sandy silt TILL, some gravel; moist.</column>
				<column name="PlainDescription">Dense grey-brown sandy silt TILL, 
some gravel; moist.
</column>
				<column name="Classification"></column>
				<column name="Lithology">Glacial Till</column>
				<column name="Color">Grey Brown</column>
				<column name="Odour">Not Perceptible</column>
				<column name="Porosity"></column>
				<column name="Consistency">Dense</column>
				<column name="VertAlign">3</column>
				<column name="HorzAlign">6</column>
				<column name="TitleHAlign">6</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">1</column>
				<column name="LineColor">0</column>
				<column name="StratumCode">1</column>
				<column name="StratumLibrary">USCS</column>
				<column name="StratumCode2">0</column>
				<column name="StratumLibrary2"></column>
				<column name="ContactAngle">0</column>
				<column name="FillSize">1</column>
				<column name="FillSize2">1</column>
				<column name="StratumFGColor">0</column>
				<column name="StratumBGColor">14965</column>
				<column name="StratumFGColor2">0</column>
				<column name="StratumBGColor2">16777215</column>
				<column name="StratumLineStyle">6</column>
				<column name="StratumLineWidth">1</column>
				<column name="StratumLineColor">0</column>
				<column name="SplitAngle">90</column>
				<column name="PercentageSplit">50</column>
				<column name="SplitLineStyle">0</column>
				<column name="SplitLineColor">0</column>
				<column name="SplitLineWidth">1</column>
			</entry>
		</table>
		<table name="LOG_MapExtents">
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Xmin">0</column>
				<column name="Xmax">0</column>
				<column name="Ymin">0</column>
				<column name="Ymax">0</column>
			</entry>
		</table>
		<table name="LOG_Remarks">
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">USCS / AASHTO Classification</column>
				<column name="Units"></column>
				<column name="DatasetType">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Moisture Content</column>
				<column name="Units">%</column>
				<column name="DatasetType">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Optimum Moisture Content</column>
				<column name="Units">%</column>
				<column name="DatasetType">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">California Bearing Ratio</column>
				<column name="Units">%</column>
				<column name="DatasetType">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">% Passing 200 Sieve</column>
				<column name="Units">%</column>
				<column name="DatasetType">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">% Passing Sieve</column>
				<column name="Units">%</column>
				<column name="DatasetType">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Moisture / Compaction</column>
				<column name="Units"></column>
				<column name="DatasetType">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Transportation Laboratory Results</column>
				<column name="Units"></column>
				<column name="DatasetType">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">QA/QC Findings</column>
				<column name="Units"></column>
				<column name="DatasetType">0</column>
			</entry>
		</table>
		<table name="LOG_Remarks_Text">
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">USCS / AASHTO Classification</column>
				<column name="Idx">1</column>
				<column name="Depth">0.3</column>
				<column name="Remark">GW-GM / A-1-a</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">USCS / AASHTO Classification</column>
				<column name="Idx">2</column>
				<column name="Depth">0.8</column>
				<column name="Remark">GP-GM / A-1-b</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">USCS / AASHTO Classification</column>
				<column name="Idx">3</column>
				<column name="Depth">2.2</column>
				<column name="Remark">CL / A-6</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">USCS / AASHTO Classification</column>
				<column name="Idx">4</column>
				<column name="Depth">7</column>
				<column name="Remark">SM / A-2-4</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Moisture Content</column>
				<column name="Idx">1</column>
				<column name="Depth">0.4</column>
				<column name="Remark">5.8</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Moisture Content</column>
				<column name="Idx">2</column>
				<column name="Depth">1</column>
				<column name="Remark">8.4</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Moisture Content</column>
				<column name="Idx">3</column>
				<column name="Depth">2.2</column>
				<column name="Remark">22.6</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Optimum Moisture Content</column>
				<column name="Idx">1</column>
				<column name="Depth">2.2</column>
				<column name="Remark">17.5</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">California Bearing Ratio</column>
				<column name="Idx">1</column>
				<column name="Depth">0.4</column>
				<column name="Remark">82</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">California Bearing Ratio</column>
				<column name="Idx">2</column>
				<column name="Depth">2.2</column>
				<column name="Remark">3</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">% Passing 200 Sieve</column>
				<column name="Idx">1</column>
				<column name="Depth">1</column>
				<column name="Remark">11.5</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Moisture / Compaction</column>
				<column name="Idx">1</column>
				<column name="Depth">0.4</column>
				<column name="Remark">Moisture 5.8%; 98% Standard Proctor MDD.</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Moisture / Compaction</column>
				<column name="Idx">2</column>
				<column name="Depth">1</column>
				<column name="Remark">Moisture 8.4%; 94% Standard Proctor MDD.</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Moisture / Compaction</column>
				<column name="Idx">3</column>
				<column name="Depth">2.2</column>
				<column name="Remark">Moisture 22.6%; above optimum by 5.1%.</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Transportation Laboratory Results</column>
				<column name="Idx">1</column>
				<column name="Depth">0.4</column>
				<column name="Remark">Gradation meets Granular A; LA abrasion 28%; CBR 82%.</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Transportation Laboratory Results</column>
				<column name="Idx">2</column>
				<column name="Depth">1</column>
				<column name="Remark">Gradation outside Granular B envelope at No. 200 sieve; 11.5% passing.</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">Transportation Laboratory Results</column>
				<column name="Idx">3</column>
				<column name="Depth">2.2</column>
				<column name="Remark">LL 38%; PI 19%; CBR 3%; sulfate 0.06%.</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">QA/QC Findings</column>
				<column name="Idx">1</column>
				<column name="Depth">1.7</column>
				<column name="Remark">WARNING: Subgrade moisture content exceeds optimum moisture content</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">QA/QC Findings</column>
				<column name="Idx">2</column>
				<column name="Depth">2.6</column>
				<column name="Remark">WARNING: CBR is below the applicable design criteria</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">QA/QC Findings</column>
				<column name="Idx">3</column>
				<column name="Depth">4.8</column>
				<column name="Remark">ERROR: Duplicate sample ID detected.</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="RemarkType">QA/QC Findings</column>
				<column name="Idx">4</column>
				<column name="Depth">6.3</column>
				<column name="Remark">ERROR: Sample ID is required.</column>
			</entry>
		</table>
		<table name="LOG_Samples">
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">1</column>
				<column name="Depth">0.3</column>
				<column name="SampleNumber">BH05-GB-01</column>
				<column name="Type">BULK</column>
				<column name="NValue"></column>
				<column name="Recovery">90</column>
				<column name="Northing">0</column>
				<column name="Easting">0</column>
				<column name="Length">0.35</column>
				<column name="TypeCode">23</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">0</column>
				<column name="LineColor">0</column>
				<column name="FGColor">0</column>
				<column name="BGColor">0</column>
				<column name="Linked">0</column>
				<column name="USID"></column>
				<column name="Lithology">Granular Base</column>
				<column name="DryWeight">0</column>
				<column name="WetWeight">0</column>
				<column name="WeightUnits"></column>
				<column name="Color"></column>
				<column name="Odour"></column>
				<column name="Porosity"></column>
				<column name="Consistency">Compact</column>
				<column name="VOC">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">2</column>
				<column name="Depth">1.5</column>
				<column name="SampleNumber">BH05-SS-01</column>
				<column name="Type">SS</column>
				<column name="NValue">4 6 7</column>
				<column name="Recovery">75</column>
				<column name="Northing">0</column>
				<column name="Easting">0</column>
				<column name="Length">0.6</column>
				<column name="TypeCode">23</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">0</column>
				<column name="LineColor">0</column>
				<column name="FGColor">0</column>
				<column name="BGColor">0</column>
				<column name="Linked">0</column>
				<column name="USID"></column>
				<column name="Lithology">Silty Clay</column>
				<column name="DryWeight">0</column>
				<column name="WetWeight">0</column>
				<column name="WeightUnits"></column>
				<column name="Color"></column>
				<column name="Odour"></column>
				<column name="Porosity"></column>
				<column name="Consistency">Firm</column>
				<column name="VOC">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">3</column>
				<column name="Depth">3</column>
				<column name="SampleNumber">BH05-SS-02</column>
				<column name="Type">SS</column>
				<column name="NValue">6 8 9</column>
				<column name="Recovery">82</column>
				<column name="Northing">0</column>
				<column name="Easting">0</column>
				<column name="Length">0.6</column>
				<column name="TypeCode">23</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">0</column>
				<column name="LineColor">0</column>
				<column name="FGColor">0</column>
				<column name="BGColor">0</column>
				<column name="Linked">0</column>
				<column name="USID"></column>
				<column name="Lithology">Silty Clay</column>
				<column name="DryWeight">0</column>
				<column name="WetWeight">0</column>
				<column name="WeightUnits"></column>
				<column name="Color"></column>
				<column name="Odour"></column>
				<column name="Porosity"></column>
				<column name="Consistency">Stiff</column>
				<column name="VOC">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">4</column>
				<column name="Depth">4.5</column>
				<column name="SampleNumber">BH05-SS-02</column>
				<column name="Type">SS</column>
				<column name="NValue">8 11 13</column>
				<column name="Recovery">88</column>
				<column name="Northing">0</column>
				<column name="Easting">0</column>
				<column name="Length">0.6</column>
				<column name="TypeCode">23</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">0</column>
				<column name="LineColor">0</column>
				<column name="FGColor">0</column>
				<column name="BGColor">0</column>
				<column name="Linked">0</column>
				<column name="USID"></column>
				<column name="Lithology">Silty Clay</column>
				<column name="DryWeight">0</column>
				<column name="WetWeight">0</column>
				<column name="WeightUnits"></column>
				<column name="Color"></column>
				<column name="Odour"></column>
				<column name="Porosity"></column>
				<column name="Consistency">Stiff</column>
				<column name="VOC">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">5</column>
				<column name="Depth">6</column>
				<column name="SampleNumber"></column>
				<column name="Type">SS</column>
				<column name="NValue">14 18 21</column>
				<column name="Recovery">70</column>
				<column name="Northing">0</column>
				<column name="Easting">0</column>
				<column name="Length">0.6</column>
				<column name="TypeCode">23</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">0</column>
				<column name="LineColor">0</column>
				<column name="FGColor">0</column>
				<column name="BGColor">0</column>
				<column name="Linked">0</column>
				<column name="USID"></column>
				<column name="Lithology">Glacial Till</column>
				<column name="DryWeight">0</column>
				<column name="WetWeight">0</column>
				<column name="WeightUnits"></column>
				<column name="Color"></column>
				<column name="Odour"></column>
				<column name="Porosity"></column>
				<column name="Consistency">Dense</column>
				<column name="VOC">0</column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">6</column>
				<column name="Depth">9</column>
				<column name="SampleNumber">BH05-SS-05</column>
				<column name="Type">SS</column>
				<column name="NValue">18 24 28</column>
				<column name="Recovery">68</column>
				<column name="Northing">0</column>
				<column name="Easting">0</column>
				<column name="Length">0.6</column>
				<column name="TypeCode">23</column>
				<column name="LineStyle">0</column>
				<column name="LineWidth">0</column>
				<column name="LineColor">0</column>
				<column name="FGColor">0</column>
				<column name="BGColor">0</column>
				<column name="Linked">0</column>
				<column name="USID"></column>
				<column name="Lithology">Glacial Till</column>
				<column name="DryWeight">0</column>
				<column name="WetWeight">0</column>
				<column name="WeightUnits"></column>
				<column name="Color"></column>
				<column name="Odour"></column>
				<column name="Porosity"></column>
				<column name="Consistency">Dense</column>
				<column name="VOC">0</column>
			</entry>
		</table>
		<table name="LOG_Text">
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">1</column>
				<column name="Type">TRANSPORTATION INVESTIGATION LOG:</column>
				<column name="Value">BH-05 TRANS-QAQC</column>
				<column name="DataType">3</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">2</column>
				<column name="Type">PROJECT:</column>
				<column name="Value">Validation QA and QC Examples</column>
				<column name="DataType">5</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">3</column>
				<column name="Type">CONTRACT / PROJECT NO.:</column>
				<column name="Value">DOT-QAQC-DEMO-001</column>
				<column name="DataType">6</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">4</column>
				<column name="Type">DATE:</column>
				<column name="Value">2026-08-14</column>
				<column name="DataType">14</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">5</column>
				<column name="Type">SURFACE ELEVATION:</column>
				<column name="Value">312.6</column>
				<column name="DataType">11</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">6</column>
				<column name="Type">EASTING:</column>
				<column name="Value">568420.5</column>
				<column name="DataType">7</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">7</column>
				<column name="Type">NORTHING:</column>
				<column name="Value">4812435.8</column>
				<column name="DataType">8</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">8</column>
				<column name="Type">VALIDATION STATUS:</column>
				<column name="Value">Failed</column>
				<column name="DataType">0</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">9</column>
				<column name="Type">COMPLETENESS:</column>
				<column name="Value">72%</column>
				<column name="DataType">0</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">10</column>
				<column name="Type">CONFIDENCE:</column>
				<column name="Value">54%</column>
				<column name="DataType">0</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">11</column>
				<column name="Type">QA/QC STATE:</column>
				<column name="Value">In Progress</column>
				<column name="DataType">0</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">12</column>
				<column name="Type">ROUTE / HIGHWAY:</column>
				<column name="Value">Highway 7 Eastbound</column>
				<column name="DataType">0</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="Idx">13</column>
				<column name="Type">STATION / CHAINAGE:</column>
				<column name="Value">12+450</column>
				<column name="DataType">0</column>
				<column name="Checked">0</column>
				<column name="AGSType"></column>
			</entry>
		</table>
		<table name="LOG_WellType3">
			<entry>
				<column name="BoreholeID">Validation QA and QC Examples:BH-05 TRANS-QAQC</column>
				<column name="WellNumber">Well</column>
				<column name="WellDiameter">0</column>
				<column name="WellWidth">40</column>
				<column name="WellOffset">30</column>
				<column name="SealBorderColor">0</column>
				<column name="SealBorderWidth">1</column>
				<column name="SealBorderStyle">0</column>
				<column name="WaterDepthFromCasingTop">0</column>
				<column name="CasingTop">0</column>
				<column name="WaterLevelDisplay">0</column>
				<column name="ShowDepth">1</column>
				<column name="IgnoreWaterStrikes">0</column>
				<column name="ScreenType"></column>
				<column name="ScreenMaterial"></column>
				<column name="ScreenStart">0</column>
				<column name="ScreenEnd">0</column>
				<column name="GroutType"></column>
				<column name="CoverType"></column>
			</entry>
		</table>
	</tables>
</borehole>
